  1. The maximum number of VCs that can be configured for Series 300/400
  2. machines with a DIO backplane is 32/card.  If a packet size of 256 bytes is
  3. configured, the maximum number of VCs is 16/card.  If the fast select
  4. facility is enabled, the maximum number of VCs is 16/card.
  5.  
  6. The maximum number of VCs that can be configured for Series 800 machines
  7. with a CIO (Mid-Bus) backplane is 64/card.  The maximum number of VCs that
  8. can be configured for Series 800 machines with an NIO backplane is 256/card.
  9.  
  10. The maximum number of VCs that can be configured for Series 700 machines
  11. with an EISA backplane is 256/card.
  12.  
  13. The maximum numbers of VCs that is supported on a system (whatever the number
  14. of cards) is 1024 VCs/spu.
  15.  
  16. The actual number of VCs that can be configured for a particular interface
  17. depends on the packet size, frame size and level 2 window size setting.
  18.  
  19.  
  20. MAXIMUM VCs FOR Mid-Bus PSI (CIO) all versions HP-UX and Precision-Bus PSI
  21. for HP-UX versions prior to 8.0 :
  22.  
  23.  
  24.                        LEVEL 3 Packet SIZE
  25.              _____________________________________________________________
  26. LEVEL 2    |   16    32    64    128    256    512    1024    2048    4096
  27. WINDOW     |______________________________________________________________
  28. SIZE       |
  29.           1|   64    64    64     64     56     28      14       7       3
  30.           2|   64    64    64     64     55     28      13       6       2
  31.           3|   64    64    64     64     55     27      12       5       1
  32.           4|   64    64    64     64     54     26      12       5       1
  33.           5|   64    64    64     64     53     26      11       4       0
  34.           6|   64    64    64     64     53     25      10       3       0
  35.           7|   64    64    64     64     52     24      10       3       0
  36.  
  37.  
  38.  
  39. MAXIMUM VCs for Precision-Bus PSI (NIO) and EISA bus for HP-UX 8.0 and later:
  40.  
  41.                         LEVEL 3 PACKET SIZE
  42.            _____________________________________________________________
  43. LEVEL 2  | 16    32    64    128    256    512    1024    2048    4096
  44. WINDOW   |______________________________________________________________
  45. SIZE   1 |256   256   256    256    256    236     120      64      32
  46.        2 |256   256   256    256    256    236     119      63      32
  47.        3 |256   256   256    256    256    235     119      63      31
  48.        4 |256   256   256    256    256    235     118      62      31
  49.        5 |256   256   256    256    256    234     117      61      30
  50.        6 |256   256   256    256    256    233     117      61      29
  51.        7 |256   256   256    256    256    233     116      60      29